Z-Wave Qubino ZMNHCA2 Flush Shutter

Description

This module is used to control the motor of blinds, rollers, shades, garage doors, gates, venetian blinds, etc. The module can be controlled either through a Z-Wave network or through the wall switch. Precise positioning is supported for motors equipped with mechanical or electronic end switches. The module measures the power consumption of the connected motor and supports the connection of a digital temperature sensor.


Include

  • Connect module to power supply
  • Bring module within maximum 1 meter (3 feet) of the main controller
  • enable add/remove mode on main controller
  • auto-inclusion (30 minutes after connected to power supply) or
  • press service button S for more than 2 second or  press push button I1 three times within 3s (3 times change switch state within 3 seconds)


Exclude

  • Connect module to power supply
  • bring module within maximum 1 meter (3 feet) of the main controller
  • enable add/remove mode on main controller
  • press service button S for more than 6 second or  press push button I1 five times within 3s (5 times change switch state within 3 seconds).


Tips & Tricks

Calibrating the device

To calibrate the device correctly, you need to put the roller down manually. Then you should configure the parameter 14 to 1 and this will initiate the automatic calibration (note there is a manual calibration method too explained in the manual). Once the roller has gone up, down and up again then the calibration is completed and you should set the parameter 14 back to 0.

This is required to make sure the device shows its status to Off otherwise the device will always be On meaning fully opened or dimmed.

If the device doesn't go up

If you have configure I1 instead of I2 and Q1 instead of Q2 then the device will work ok manually but will not be working normally from OpenZwave. To solve this, you just need to invert I1 with I2 and Q1 with Q2.

All parameters described at http://qubino.com/products-2/flushshutter/

Related Resources

  • See issue #538: "Qubina roller shutter always at Dim 254"

    Updated by: Anonymous, Updated over 3 years ago